''Image acquisition''  
+
''Image acquisition'' <br/>
Data were collected using a 3T Siemens Trio MRI scanner. For each task run, functional T2*-weighted echoplanar images (EPIs) were collected with the following parameters: slice thickness = 4 mm, 34 slices, TR = 2 s, TE = 30 ms, flip angle = 90°, matrix 64 x 64, FOV = 192 mm. Additionally, a T2-weighted matched-bandwidth high-resolution anatomical scan (same slice prescription as EPI) and MPRAGE were collected. The parameters for MPRAGE were the following: TR = 1.9 s, TE = 2.26 ms, FOV = 250, matrix = 256 x 256, saggital plane, slice thickness = 1 mm, 176 slices.  
+
Data were collected using a 3T Siemens Trio MRI scanner. For each task run, functional T2*-weighted echoplanar images (EPIs) were collected with the following parameters: slice thickness = 4 mm, 34 slices, TR = 2 s, TE = 30 ms, flip angle = 90°, matrix 64 x 64, FOV = 192 mm. Additionally, a T2-weighted matched-bandwidth high-resolution anatomical scan (same slice prescription as EPI) and MPRAGE were collected. The parameters for MPRAGE were the following: TR = 1.9 s, TE = 2.26 ms, FOV = 250, matrix = 256 x 256, saggital plane, slice thickness = 1 mm, 176 slices. <br/>
 
+
<br/>
The number of EPIs collected for each task are as follows:  
+
The number of EPIs collected for each task are as follows: <br/>
BART: 267
+
BART: 267 <br/>
BHT: 79
+
BHT: 79 <br/>
RESTING: 152
+
RESTING: 152 <br/>
TS: 208
+
TS: 208 <br/>
SST: 184
+
SST: 184 <br/>
SCAP: 291
+
SCAP: 291 <br/>
PAMENC: 242  
+
PAMENC: 242 <br/>
PAMRET: 268
+
PAMRET: 268 <br/>

Revision as of 10:47, 15 March 2012

Image acquisition
Data were collected using a 3T Siemens Trio MRI scanner. For each task run, functional T2*-weighted echoplanar images (EPIs) were collected with the following parameters: slice thickness = 4 mm, 34 slices, TR = 2 s, TE = 30 ms, flip angle = 90°, matrix 64 x 64, FOV = 192 mm. Additionally, a T2-weighted matched-bandwidth high-resolution anatomical scan (same slice prescription as EPI) and MPRAGE were collected. The parameters for MPRAGE were the following: TR = 1.9 s, TE = 2.26 ms, FOV = 250, matrix = 256 x 256, saggital plane, slice thickness = 1 mm, 176 slices.

The number of EPIs collected for each task are as follows:
BART: 267
BHT: 79
RESTING: 152
TS: 208
SST: 184
SCAP: 291
PAMENC: 242
PAMRET: 268